How to clean the air compressor cooler

How to clean the air compressor cooler

Each air compressor run around 2000h clear cooling surface dust, cap the cooler fan bracket purge hole open to be purged of the cooler air gun blowing dust until the cooling surface dust purged. Still serious heat surface dirt is difficult to purge and clean, remove the cooler, pour the oil cooler and four import and export closed to prevent dirt from entering, and then both sides with compressed air blowing dust or water rinse, final drying surface water stains. Back into place.
Remember! Do not scrape the dirt with a wire brush, and other hard objects, so as not to damage the radiator surface.
Condensate
The moisture in the air may condense in the oil and gas separation tank, particularly in wet weather, when the exhaust temperature is below the dew point pressure of the air or shutdown cooling, there will be more condensed water precipitated. The oil contains too much water will cause lubricating oil emulsion, affect the safe operation of the machine, such as:
1. Causing compressor Host poor lubrication
2. Oil and gas separation effects of variation, the larger oil and gas separator differential pressure
3. Cause mechanical rusting.
Therefore, should be formulated based on humidity conditions the condensate drain timetable.
Condensate discharge method
Should shut down the machine, oil separator tank pressure sufficiently cooled condensate fully precipitate, such as the morning before starting.
(1) screwed out of the bottom of the oil separator tank ball valve screw plug.
(2) Slowly open the ball valve drain, close the valve until the oil outflow.
(3) screw on the ball valve screw plug.